Temp & Humidity Series

Walk-in Constant Temperature & Humidity Room

Walk-in Constant Temperature & Humidity Room


Features

• The walk-in constant temperature and humidity chamber is mainly composed of a control panel, a switchboard, a thermal insulation board, a blower, a heater, a humidifier, and a freezer.

• The multi-blade blower is used for strong air circulation to avoid any dead angle and ensure uniform distribution of indoor temperature and humidity.

• Convenient and fast automatic water supply system, filtered by reverse osmosis pure water machine, automatically replenishing humidification water without manual operation.

• The box circuit system, water system and refrigeration system are modularly distributed to ensure safe and reliable operation.


Applicable Standards

Chinese Standard

GB/T2423.1-2008 Environmental test of electrical and electronic products Part 2: Test A: Low temperature test method

GB/T2423.2-2008 Environmental test of electrical and electronic products Part 2: Test B: High temperature test method

GB/T2423.3-2016 Environmental test of electrical and electronic products Part 2: Test Cab: Constant damp heat test method

GB/T2423.4-2008 Environmental test for electrical and electronic products Part 2: Test Db: Test method for alternating damp heat

GJB150.3A-2009 Laboratory Environmental Test Methods for Military Equipment Part 3: High Temperature Test

GJB150.4A-2009 Laboratory Environmental Test Methods for Military Equipment Part 4: Low Temperature Test

GJB150.9A-2009 Laboratory Environmental Test Methods for Military Equipment Part 9: Damp heat test


International standard

IEC 60068-2-1:2007 "Environmental Testing Part 2-1: Tests Test A: Low Temperature" (English version)

IEC 60068-2-2:2007 "Environmental Testing Part 2-2: Test Test B: Dry Heat" (English version)

IEC 60068-2-78:2012 "Environmental Testing Part 2-78: Tests Test Cab: Constant Damp Heat Test" (English version)

IEC 60068-2-30:2005 "Environmental Testing Part 2-30: Test Test Db: Alternating Damp Heat Test" (English version)


Manufacturing Standard

GB/T10586-2006 "Technical Conditions of Damp Heat Test Chamber" and GB/T10592-2008 "Technical Conditions of High and Low Temperature Test Chamber"


Standard Test

GB/T5170.2-2017 "Inspection method of environmental test equipment for electrical and electronic products: temperature test equipment"

GB/T5170.5-2016 "Inspection method of environmental test equipment for electrical and electronic products: damp heat test equipment"


Metrological Verification Standard

JJF1101-2019 "Temperature and Humidity Calibration Specification for Environmental Test Equipment"


Specification & Technical Data

表格.jpg


*1: Average rate between maximum temperature and minimum temperature (no load, no heat dissipation, refer to IEC60068-3-5)

*2: The performance index is measured when the room temperature is +25°C; the sensor is at the air outlet of the air handling unit

Note: The above specifications and dimensions are for reference only, and the actual production shall prevail.



  |  Home
Products
Temp.& Humidity ...
Thermal Cycling S...
High Temp Aging ...
Precision Constant...
Other Environmen...
About BACL
Company Profile
Development History
Honors & Certificates
News
Company News
Industry News
Our Clients
Our Clients
Contact us

 12, Pulong East 1st Road, Tangxia Town, Dongguan, Guangdong, China
 0769-86858888 ext.5201
 testequipment@baclcorp.com
 www.bacldesign.com